What is Grounding and Why Is It Needed?
November 22, 2021 | ftadmin
A single lightning strike can contain as many as one billion volts. The sheer power and frequency of lightning strikes make them a serious threat to ungrounded commercial facilities and homes. But wha...
Read More
Transient Noise and Impedance of a Grounding Electrode
January 27, 2021 | VFC LP Staff
Abstract High-speed electronics today allow us to see the distant planets, map the human genome, fly drones thousands of miles away, deploy semi-autonomous vehicles, have mobile access to the interne...
Read More
An Economic Case for Facility Lightning Protection Systems in 2021
August 31, 2020 | VFC LP Staff
An economic case for facility lightning protection systems in 2021. Lightning strikes the earth 100 times every second— that’s more than 8 million times a day. In the United States al...
Read More
Lightning Protection Codes, Standards, and Regulations
July 15, 2020 | VFC LP Staff
One of the most significant dangers to buildings and construction sites is lightning. The sheer power and voltage behind a lightning strike can cause extreme fires, electrocution, and extensive damage...
Read More
Lightning Protection System Inspection and Maintenance
July 9, 2020 | VFC LP Staff
Your lightning protection design engineer has taken special precautions to provide corrosion protection, along with sizing the components according to their specific exposure to potential lightning da...
Read More
Lightning Risk Assessments: What You Need to Know
July 1, 2020 | VFC LP Staff
Though the National Electrical Code (NEC) and most local building codes do not require lightning protection, property owners and facility managers would benefit from installing lightning protection. B...
Read More
Facility Lightning Protection – Structures vs. Systems
June 17, 2020 | VFC LP Staff
The risk of lightning damage and disruption to US industry and property is continually rising. Costs of lightning related damage are currently estimated at $8 billion to $10 billion annually (1), and ...
Read More
Causes and Mitigation of Corrosion on Buried Copper
June 17, 2020 | VFC LP Staff
Everyone, at sometime in their life has probably found an old penny on the ground and picked it up. Unless you are lucky enough to find a 1943 penny, it was made of between 88% and 95% copper. When th...
Read More
Early Streamer Emission Air Terminal (ESEAT) Systems Fact vs Fiction
June 9, 2020 | VFC LP Staff
The cost of Lightning 1. Risk of Lightning Damage and disruption grows each year, costs growing at 20% per/yr, costs at $8 to $10 billion annually. 2. Application of a comprehensive Facility L...
Read More
How Grounding System Testing Works
June 9, 2020 | VFC LP Staff
The grounding system in a typical home consists of the equipment grounding conductors and grounding electrode that are connected to a common bonding point with the neutral from the incoming power, the...
Read More
What is Soil Resistivity Testing?
June 3, 2020 | VFC LP Staff
The ability of a grounding system to conduct a fault current into the soil is directly dependent on the resistivity of the soil. Knowing the soil resistivity is the first and most important step in an...
Read More
How Do Grounding Electrodes Work?
June 3, 2020 | VFC LP Staff
Grounding electrodes are an important part of any grounding system. They are the method in which the system uses to dissipate fault current into the earth. How Electrodes Assist Grounding S...
Read More